Development of an Improved Vapour Compression Refrigeration System for Preservation of fresh Vegetables

Authors
  • T. S. Mogaji

    Department of Mechanical Engineering, Federal University of Technology, Akure

Keywords:
Vapour compression refrigerator system, Temperature control device, temperature, relative humidity, bitter leaf, pumpkin leaf
Abstract

An improved vapour compression refrigeration system (VCRS) was developed for the preservation of fresh vegetables and its performance was evaluated. The cooling system operating with R134a as working fluid consists of an evaporator, compressor, condenser, capillary tube and a redesigned temperature control device (TCD). The refrigeration system has capacity to accommodate 0.02 metric tonnes (20 kg) of any fresh vegetables. The improved cooling system was used to preserve fresh vegetables such as: bitter leaf (Vernonia  amygdalina Delile) and pumpkin leaf (Telfairia occidentalis). Study was conducted to check the freshness of the vegetables and data were observed daily. Results of the transient performance tests revealed that an average cabinet and ambient temperature of 3.64C and 26.89C were observed, and an average cabinet and ambient relative humidity of 94.50% and 45.23% were recorded respectively for the preserved vegetables. The needed optimum storage temperature range for the preservation of the selected vegetables samples were attained in cooling system at 2C – 4C with the aids of the incorporated newly designed TDC. The improved domestic vapour compression refrigeration system performed up to expectation as the shelf life of the tested sample inside the cooling system was extended by fourteen days relative to ambient storage.

References
Cover Image
Downloads
Published
2019-05-14
Section
Articles
License

Copyright

With the submission of a manuscript, the corresponding author confirms that the manuscript is not under consideration by another journal. With the acceptance of a manuscript, the Journal reserves the exclusive right of publication and dissemination of the information contained in the article. The veracity of the paper and all the claims therein is solely the opinion of the authors not the journal.

How to Cite

Development of an Improved Vapour Compression Refrigeration System for Preservation of fresh Vegetables. (2019). FUTA JOURNAL OF ENGINEERING AND ENGINEERING TECHNOLOGY, 13(1), 1-11. https://doi.org/10.51459/futajeet.2019.13.1.134

Similar Articles

61-70 of 76

You may also start an advanced similarity search for this article.