Foundational Steel Reinforcement Earthing Evaluation: Case of Ogomudia Electrical/Electronics Laboratory Building Extension, Federal University Of Technology, Akure

Authors
  • M. O. Oyeleye

    Department of Electrical and Electronics Engineering, Federal University of Technology, Akure, Nigeria

  • T. O. Ale

    Department of Electrical and Electronics Engineering, Federal University of Technology, Akure, Nigeria

Keywords:
Soil Resistivity, Earthing, Safety, Steel Reinforcing
Abstract

This paper focuses on foundation steel reinforcement for safe earthing in homes and industries. This will establish the safe limit of voltage or potential difference that can allow equipment to operate without injury to personnel and equipment. The earthing system of Ogomudia Electrical/Electronic Laboratory building extension, Federal University of Technology, Akure(FUTA), was evaluated for the purpose of proposing the earthing system that will be able to meet the primary objective of earthing and sustain the building for 80 years and above without deterioration as against the conventional earthing. Three (3) points fall of potential) method was used in evaluating the resistance of each column steel reinforcement thereby measuring the earthing scheme dispersing proficiency. A comparism of the dissipation capability using the resistance values of the conventional earthing system and an interconnected foundation steel reinforcement with the conventional earthing system was carried out using a digital earth tester. The result obtained showed that the interconnected foundational steel reinforcement with the conventional earthing system has the lowest resistance of 2.8 ohms; and earthing system looped together gave 1.75 ohms which conforms to British Standard Institution (BSI) of 10 ohms and International Electrochemical Commission of 4 ohms. This shows that the effect of foundation steel reinforcement lowers the conventional earth resistance by 162%. The result also revealed that the foundational steel reinforcement resistance is 7.42 times better than the conventional earthing resistance of the studied area. It is therefore recommended that advantage of foundation steel reinforcement (where it exists) should be taken and interconnected with the conventional earthing.

References
Cover Image
Downloads
Published
2019-05-14
Section
Articles
License

Copyright

With the submission of a manuscript, the corresponding author confirms that the manuscript is not under consideration by another journal. With the acceptance of a manuscript, the Journal reserves the exclusive right of publication and dissemination of the information contained in the article. The veracity of the paper and all the claims therein is solely the opinion of the authors not the journal.

How to Cite

Foundational Steel Reinforcement Earthing Evaluation: Case of Ogomudia Electrical/Electronics Laboratory Building Extension, Federal University Of Technology, Akure. (2019). FUTA JOURNAL OF ENGINEERING AND ENGINEERING TECHNOLOGY, 13(1), 96-102. https://doi.org/10.51459/futajeet.2019.13.1.143

Similar Articles

11-20 of 37

You may also start an advanced similarity search for this article.