EXPERIMENTAL INVESTIGATION OF OUTDOOR AIR QUALITY AT A TERTIARY INSTITUTION GATE

Authors
  • Asani, M. A

    Ladoke Akintola University Technology, Ogbomoso, Nigeria

  • Idi, M. D

    B105 Ramat Shopping Complex, Maiduguri, Borno State, Nigeria

  • Oke, I. A

    Obafemi Awolowo University, Ile -Ife, Nigeria

Keywords:
Array, Array, Array, Array, Array
Abstract

Air pollution is the reduction in the outdoor or indoor environment quality by any physical, biological or chemical agents above the ambient level that can modify the natural characteristics of the atmosphere. Air pollution can cause long-term and short-term health effects. In this paper air quality of an institutional environment was evaluated and presented based on selected air pollutants, air quality indices (AQI), hazard ratio and lifetime cancer risk. Air quality measurements were conducted at Obafemi Awolowo University Road 1gate for three months. The Air quality indices were computed using standard methods and procedures. The study revealed that mean, skewness and kurtosis of temperature, relative humidity, total organic compounds (TVOC), Carbon dioxide (CO ) and HCHO were temperature (34.2, 34.3oC; 0.6 and 0.6; -0.4 and -0.4); relative humidity (35.46 and 39.23

%; 1.52 and 1.54; and 1.67 and 1.73),TVOC (0.753 ppm and 0.660 ppm; 1.501 and 1.541; and 1.331 and 1.116), CO2 (926.77ppm and 803.77 ppm; -0.70 and -0.63; -1.27, and -1.22) and HCHO (0.051 ppm and 0.048 ppm; 1.123 and 1.51; and 0.504 and 1.69), respectively. AQI for CO2, TVOC and HCHO were between 135 and 336, 16.72 and 173.02, 12.37, and 2191.42, respectively. Life cancer risk for CO , TVOC and HCHO were between 2.42 x 10-3 and

-3                                 -6                                            -5                                 -8                                             -6              2

6.02 x 10 , 2.36 x 10 and 9.06 x 10 , 2.63 x 10 and 2.36 x 10 respectively.

It was concluded that AQI in-term of CO2 was high (poor and polluted) but fair for TVOC and HCHO. There is a need to reduce CO2 concentration as an increase in CO concentration has been associated with cardiovascular diseases, high blood pressure and chronic kidney disease.

 

 

 

Author Biographies
  1. Asani, M. A, Ladoke Akintola University Technology, Ogbomoso, Nigeria

    Department of Urban and Regional Planning

  2. Idi, M. D, B105 Ramat Shopping Complex, Maiduguri, Borno State, Nigeria

    Land, Air and Water Consulting Engineers

  3. Oke, I. A, Obafemi Awolowo University, Ile -Ife, Nigeria

    Department of Civil Engineering

References

Apte, M.G, Fisk, W.J, and Daisey, J.M (2000) A s s o c i a t i o n s B e t w e e n I n d o o r ( C O 2 ) Concentrations and Sick Building Syndrome Symptoms in US Office Buildings: an analysis of the 1994–1996 BASE Study Data (LBNL 44385). Indoor Air 10:246–257.

Baris, A., Rengin, E. A. , Asiye, K., Adrian, C., Alberto, O. and Mehmet, K. (2019). Air Pollution and Kidney Disease: review of current evidence. Clinical Kidney Journal,12 (1), 19–32.

Beelen, R., Raaschou-Nielsen, O., Stafoggia, M., Andersen, Z.J. and Weinmayr, G. (2013). Effects of Long-term Exposure to Air Pollution on Natural-cause Mortality: an analysis of 22 European cohorts within the multicentre ESCAPE project. Lancet 383 (9919): 785-795.

Bruce, N., Perez-Padilla, R., and Albalak, R. (2000) Indoor Air Pollution in Developing Countries: A Major Environmental and Public Health Challenge. Bulletin of World Health Organisation 78(9), 1078-1092

Burton, B. T. (1997) Volatile Organic Compounds. In: Bardana, E.J, Montanaro, A. (eds) Indoor Air Pollution and Health. Marcel Dekker, New York, pp 127–153

Canha, N., Martinho, M., Almeida-Silva, M., Freitas, M.D.C., Almeida, S.M., Pegas, P., Alves, C., Pio, C., Trancoso, M.A., Sousa, R., Mouro, F. and Conteiras, T. (2012) 'Indoor Air Quality in Primary Schools', International. Journal. Environment and Pollution, 50 (1/2/3/4), 396–410.

Clements-Croome, D. (2006) Ventilation Rates in Schools. Build Environ 43(3):362–367

Da Cunha, A. R. (2015). Evaluation of Measurement Errors of Temperature and Relative Humidity from HOBO Data Logger Under Different Conditions of Exposure to Solar Radiation. Environmental Monitoring and Assessment, 187(5), 1-11

Daisey, J.M, Angell, W.J, and Apte, M.G. (2003) Indoor Air Quality, Ventilation and Health Symptoms in Schools: An Analysis of Existing Information. Indoor Air 13:53–64

Dymond, E. E. (2007). Table of Relative Humidity. Quarterly Journal of the Royal Meteorological Society, 7(37), 1–3.

Fezari, M., Hattab, R. and Al-Dahoud, A. (2015) Oak Ridge Air Quality Index Computation: A Way for Monitoring Pollutions in Annaba City. The International Arab Conference on Information Technology (ACIT'2015), Isra University, 1 -12

Gianluigi de G. Paolo, R. D, Annamaria, D. L., Alessia, D. G., Pasquale, G., Maria, T., Annalisa, M., Antonio, M, Jolanda, P. and Francesca, P. (2014). Indoor air quality in schools. Environ Chem Lett . 1-16

Gianluigi de G., Genoveffa, F., Annalisa, M., Antonio, M. and Godwin C, Batterman S (2007) Indoor Air Quality in Michigan Schools. Indoor Air 17:109–121

Gorai, A.K., Kanchan, Upadhyay, A., and Goyal, P. (2014a) Design of Fuzzy Synthetic Evaluation Model For Air Quality Assessment. Environment Systems and Decisions 34, 456-469.

Gorai, A.K., Tuluri, F., and Tchounwou, P.B. (2014b) A GIS Based Approach for Assessing the Association between Air Pollution and Asthma in New York State, USA. International Journal Environmental Research and Public Health.11(5), 4845-4869.

Gorai, K.A.K and Goyal, P. (2015). A Review on Air Quality Indexing System. Asian Journal of Atmospheric Environment (9-2), 101-113.

Gupta, P. K., and Patel, R. N. (2017). A Teaching-Learning Tool For Elementary Psychrometric Processes On Psychrometric Chart Using MATLAB. Computer Applications in Engineering Education, 25(3), 458–467

Hanoune, B., LeBris, T., Allou, L, Marchand, C., and Calve, L. S. (2006) Formaldehyde Measurements in Libraries: Comparison Between Infrared Diode Laser Spectroscopy and A DNPH-Derivatization M e t h o d . A t m o s p h e re E n v i ro n m e n t 40:5768–5775

Hird, R., and Bolton, M. D. (2016). Measurement of Relative Humidity to Monitor Salt Migration in Unsaturated Porous Media. Transport in Porous Media, 112(3), 749–763.

Hoek, G., Krishnan, R.M., Beelen, R., Peters, A., Ostro, B., Brunekreef, B., and Kaufman, J.D. (2013). Long-term Air Pollution Exposure and Cardiorespiratory Mortality: A Review. Environmental Health, 12: 43 - 45.

Irgum, K. (1983). Instrument For Relative Humidity M e a s u r e m e n t . A n a l y t i c a l Chemistry,55(7),1186–1187.

James, W. L., Winnie, K., Ralph, J. D., James, J. S. and Constantinos, S (2012) Characterization of Organic, Metal and Trace Element PM2.5 Species and Derivation of Freeway-Based Emission Rates in Los Angeles, CA. Science of the Total Environment 435–436, 159–166

Jones, A.P. (1999) Indoor Air Quality and Health. Atmospheric Environment. 33(28):4535–4564

Komolafe, A.A., Adegboyega, S.A., Anifowose, A.Y.B., Akinluyi, F.O., and Awoniran, D.R. (2014). Air Pollution and Climate Change in Lagos, Nigeria: Needs for Proactive Approaches to Risk Management and Adaptation. American Journal of Environmental Sciences, 10 (4): 412-423.

Kotzias, D (2005) Indoor Air and Human Exposure Assessment—Needs and Approaches. Exposure Toxicology Pathology. 57:5–7

Leal-Junior, A., Frizera-Neto, A., Marques, C., and Pontes, M. (2018). Measurement of Temperature and Relative Humidity with Polymer Optical Fiber Sensors Based on the Induced Stress-Optic Effect. Sensors, 18(3), 916: 1 – 12.

Lee, K,, Parkhurst, W.J., Xue, J, Ozkaynak, A., Neuberg, D., and Spengler, J.D (2004) Outdoor/Indoor/Personal Ozone Exposures of Children in Nashville, Tennessee. Air Waste Management Association 54:352–359

Maria, T.. (2013) Indoor and Outdoor Monitoring of Volatile Organic Compounds in School Buildings: Indicators Based on Health Risk Assessment to Single out Critical Issues. International. Journal. Environment Resources. Public Health, 10, 6273-6291.

Mentese, S, and Gullu, G. (2006) Variations and Sources of Formaldehyde Levels in Residential Indoor Air in Ankara, Turkey. Indoor Built Environment 15:273–281

Mi, Y.H, Norback, D, Tao, J, Mi, Y.L,and Ferm, M. (2006) Current Asthma and Respiratory Symptoms among Pupils in Shanghai, China: Influence of Building Ventilation, Nitrogen Dioxide, Ozone, and Formaldehyde in Classrooms. Indoor Air 16(6):454–464.

Murmu, S. B., and Mishra, H. N. (2016). Measurement and Modelling the Effect of Temperature, Relative Humidity and Storage Duration on the Transpiration Rate of Three Banana Cultivars. Scientia Horticulturae, 209, 124–131.

Njoku, K.; Longinus, R., Tosin, J. Akinola, M.; Olatunde, A, Adeola A., and Jolaoso, A. O. (2016). Ambient Air Quality Monitoring in Metropolitan City. J. Appl. Sci. Environ. Manage. 20(1), 178 –185.

Owoade, O.K., Fawole, O.G., Olise, F.S., Ogundele, L.T., Olaniyi, H.B., Almeida, M.S., Ho, M., and Hopke, P.K. (2013). Characterization and Source Identification of Airborne Particulate Loadings at Receptor Site Classes of Lagos Mega-City, Nigeria. Journal of the Air and Waste Management Association, 63:9: 1026-1035.

Pegas P.N, Alves, C.A, Evtyugina, M.G, Nunes, T, Cerqueira, M, Franchi, M, Pio, C.A, Almeida, S.M, and Freitas, M.C (2011a) Indoor Air Quality in Elementary Schools of Lisbon In Spring. Environ Geochem Health 33(5):455–468

Pegas P.N, Alves, C.A, Evtyugina, M.G, Nunes, T, Cerqueira, M, Franchi, M, Pio, C.A, Almeida, S.M, Verde, S.C, and Freitas, M. C. (2011b) Seasonal Evaluation of Outdoor/Indoor Air Quality in Primary Schools in Lisbon. Journal Environment Monitoring. 13(3):657–667

Pegas, P. N, Nunes, T, Alves, C. A, Silva, J. R, Vieira, S.L.A, Caseiro, A., and Pio, C.A (2012) Indoor and outdoor characterisation of organic and inorganic compounds in city centre and suburban elementary schools of Aveiro, Portugal. Atmos Environ 55:80–89

Pegas PN, Evtyugina MG, Alves CA, Nunes T, Cerqueira M, Franchi M, Pio C, Almeida SM, Freitas M (2010) Outdoor/Indoor Air Quality in Primary Schools in Lisbon: a preliminary study. Quim Nova 33(5):1145–1149

Pinto, J. A. V., Schorr, M. R. W., Thewes, F. R., Ceconi, D. L., Both, V., Brackmann, A., and Fronza, D. (2015). Relative Humidity During Cold Storage on Postharvest Quality of “Niagara Rosada” Table Grapes. Ciência Rural, 45(3), 386–391.

Priscilla, N., Pegas, M., Evtyugina, G., Alves, C. A, Nunes, T., Cerqueira, M., Franchi, M., and Pio, C. (2010) Outdoor/Indoor Air Quality in Primary Schools in Lisbon: A Preliminary Study. Quim Nova 33(5):1145–1149

Righi, E., Aggazzotti, G., Fantuzzi, G., and Ciccarese, P.G (2002) Air Quality and Well-Being Perception in Subjects Attending University Libraries in Modena (Italy). Science Total Environment. 286:41–50

Rudnick, S., and Milton, D.K (2003) Risk of Indoor Airborne Infection Transmission Estimated from Carbon Dioxide Concentration. Indoor Air 13:237–245

Shendell, D.G, Prill, R, Fisk, W.J, Apte, M.G, Blake, D., and Faulkner, D. (2004) Associations between Smedje, G., Norback, D., and Edling, C. (1997b) Subjective Indoor Air Quality in Schools in Relation to Exposure. Indoor Air 7:143–150

Smith, K.R., Samet, J.M., Romieu, I., and Bruce, N. (2000) Indoor Air Pollution in Developing Countries and Acute Lower Respiratory Infections in Children. Thorax 55(6), 518-532.

Sofuoglu, A., Kiymet, N., Kavcar, P., and Sofuoglu, S.C. (2010) Polycyclic and Nitro Musks in Indoor Air: A Primary School Classroom and A Women's Sport Center. Indoor Air 20:515–522.

Sofuoglu, S.C., Aslan, G., and Inal, F. (2011) An assessment of Indoor Air Concentrations and Health Risks of Volatile Organic Compounds in Three Primary Schools. International Journal Hygiene Environment Health 214:38–46.

Thom, G.C., and Ott, W.R. (1976) A Proposed Uniform Air Pollution Index. Atmospheric Environment 10, 261- 264.

Thorn, C. C. and Ott, W. R. (1975), Air Pollution Index Systems in the United States and Canada. Journal of the Air Pollution Control Association, 26(5), 460 – 470.

Tiwari, P. (2015). Computational Methods of Air Quality Indices: A Literature Review. IOSR Journal of Environmental Science, Toxicology and Food Technology. 1(5), 46-49

Vaizoglu, S.A, Aycan, S., Deveci, M.A., Acer, T., Bulut, B., Bayraktar, U. D., Akyollu, B., Celik, M., Arslan, U., Akpinar, F., Baris, Z., Arslan, S., Deniz, A., Didem, E. E., and Gu¨ler, C. (2003) Determining Domestic Formaldehyde Levels in Ankara, Turkey. Indoor Built Environment 12:329–335.

WHO (2017). Evolution of WHO Air Quality Guidelines: Past, Present And Future. Copenhagen: WHO Regional Office for Europe.

Yamashita, S., Kume, K., Horiike, T., Honma, N., Masahiro, F., and Amagai, T. (2012) Emission Sources and Their Contribution to Indoor Air Pollution by Carbonyl Compounds in a School and A Residential Building in Shizuoka, Japan. Indoor Built Environment 21(3):392–402

Classroom CO2 Concentrations and Student

Yang, W., Sohn, J., Kim, J., Son, B., and Park, J., (2009) Attendance in Washington and Idaho. Indoor Air 14:333–341

Shin, M., Patton, R., Mahar, T., Ireland, A., Swan, P., and Chow, C. M. (2017). Calibration and Validation Processes for Relative Humidity Measurement by a Hygrochron Button. Physiology and Behaviour, 179, 208–212.

Smedje, G, Mattsson, M, and Walinder, R., (2011) Comparing Mixing and Displacement Ventilation in Classrooms: Pupils' Perception and Health. Indoor Air 21:454–461.

Smedje, G., Norback, D., and Edling, C. (1997a) Asthma among Secondary School Children in Relation to the School Environment. Clin Exp Allergy 27(11):1270–1278.

Indoor Air Quality Investigation According to Age of the School Buildings in Korea. Journal Environment Management 90:348–354

Yaru, S. S (2021). Pollution Of Vehicular Emission Analysis at Federal University Of Technology Akure North Gate. Journal of Engineering and Engineering Technology . FUTAJEET,15(1), 29 – 37.

Zhang, G., Spickett, J., Rumchev, K., Lee, A.H., and Stick, S., (2006) Indoor Environmental Quality in A 'Low Allergen' School and Three Standard Primary Schools in Western Australia. Indoor Air 16:74–80

Zhang, Q., and Zhu, Y., (2012) Characterizing Ultrafine Particles and Other Air Pollutants at Five Schools in South Texas. Indoor Air 22:33–42.

Zhao, Y., Li, A., Gao, R., Tao, P., and Shen, J. (2014). Measurement of Temperature, Relative Humidity and Buildings, 69, 544–561.

Zhu C.S, Cao J.J, Tsai C.J, Shen Z.X, Ho K.F, and Liu S.X (2010) The indoor and outdoor carbonaceous pollution during winter and summer in rural areas and Concentrations of CO, CO2 And TVOC of Shaanxi, China. Aerosol Air Qual Res During Cooking Typical Chinese Dishes Energy 10:550–558.

Cover Image
Downloads
Published
2026-09-09
Section
Articles
License

Copyright (c) 2022 FUTA JOURNAL OF ENGINEERING AND ENGINEERING TECHNOLOGY

Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

Copyright

With the submission of a manuscript, the corresponding author confirms that the manuscript is not under consideration by another journal. With the acceptance of a manuscript, the Journal reserves the exclusive right of publication and dissemination of the information contained in the article. The veracity of the paper and all the claims therein is solely the opinion of the authors not the journal.

How to Cite

EXPERIMENTAL INVESTIGATION OF OUTDOOR AIR QUALITY AT A TERTIARY INSTITUTION GATE. (2026). FUTA JOURNAL OF ENGINEERING AND ENGINEERING TECHNOLOGY, 16(2), 58-72. https://doi.org/10.51459/futajeet.2022.16.2.699

Similar Articles